Sorption dehumidifier DR-040-16A

Adsorptionstrockner Type DR-040-16A[/fusion_builder_column_inner]
[/fusion_text]
  • Stainless steel housing
  • SSCR sorption rotor
  • Common fan for process and regeneration air
  • With electric PTC heater with overheating protection
  • With internal heat recovery

Specifications/ instructions:

Download Specifications_DR-40-50_DE.pdf (207.54 KB)
Download Dimensions_DR-40-50R.pdf (51.37 KB)

[fusion_button link=”https://www.kirsch-tec.at/kontakt/anfrage/” color=”default” size=”” type=”” shape=”” target=”_self” title=”” gradient_colors=”

” gradient_hover_colors=”

” accent_color=”” accent_hover_color=”” bevel_color=”” border_width=”1px” shadow=”” icon=”fa-check-circle-o” icon_position=”left” icon_divider=”no” modal=”” animation_type=”0″ animation_direction=”left” animation_speed=”1″ alignment=”right” class=”” id=””]Send a request[/fusion_button]
[/fusion_text]
Dehumidification capacity at 20° C and 60% rel. humidity:2,3 kg/h
Dehumidification capacity at 30°C and 80 % rel. humidity:2,94 kg/h
Dehumidification capacity at 10°C and 70 % rel. humidity:1,61 kg/h
Dehumidification capacity at 0°C and 90 % rel. humidity:1,17 kg/h
Process airflow, nominal, at ext. pressure:
550 m³/h, pri 150 Pa ext.
Regeneration airflow, nominal, at ext. pressure:150 m³/h, bei 150 Pa ext.
Working temperature:-20 to +35 °C
Working range humidity:10 – 100 % rF
El. heating capacity, max.:3 kW
Electrical motor power, max.:0,3 kW
Total power, max.:3,3 kW
Connection voltage:1x 230V, 50 Hz
Fuse:16 A
Required switching for remote contact (e.g., hygrostat or remote ON):1 A (control voltage)
Height (total):599 mm
Width (total):670 mm
Depth (total):575 mm
Weight:50 kg
Inlet process air:160 mm
Outlet process air (dry air):160 mm
Inlet regeneration air:100 mm
Outlet regeneration air (wet air):100 mm
Rotor speed:28 1/h
Noise level, with connected ducting, 1m free-field:< 60 dB(A)
Filter class:G3
Application range:
Diverse application range, to achieve the lowest possible relative humidity, to dry air to specific value, or at low temperatures, with wet air exhaust to the outside
Working principle:RECUSORB
Installation:
Stationary, standing
Wet air exhaust:Required
Housing:Stainless steel, self standing
Maintenance accessibility:From the front and from above
Air filter, class:A common G3 filter for the process and regeneration air, can be reached quick and easy
Fan:A common chamber fan for the process and regeneration air, directly driven
Sorption rotor:
SSCR-U, d 450mm x h 50mm
Rotor drive:Rotormotor with belt drive and belt tensioner
Regeneration heating:Electrical PTC heating, self-regulating and with overheat protection, with ammeter for easy regulation of air flow
Electrical equipment:All components wired to terminal, On / Off and Man / Auto switch, with ammeter, operating hours counter and hygrostat connection socket, standard configuration
Controlling:Prepared for hygrostat connection
Signal:
Remote-ON/OFF
Supply:230V CEE cable with 2m cable
Operating hours counter:Standard
Device connection socket:Standard
Hygrostat/remote-ON: