Sorption dehumidifier R-060BR

Click edit button to change this text.

Adsorptionstrockner Type R-060BR[/fusion_builder_column_inner]
[/fusion_text]
  • Stainless steel housing
  • SSCR sorption rotor
  • Common fan for process and regeneration air
  • With electric PTC heater
  • With internal heat recovery

Specifications/Instructions:

Download Data sheet_R-060BR-DE.pdf (389.05 KB)
Download Dimensions_R-060BR.pdf (40.93 KB)

[fusion_button link=”https://www.kirsch-tec.at/kontakt/anfrage/” color=”default” size=”” type=”” shape=”” target=”_self” title=”” gradient_colors=”

” gradient_hover_colors=”

” accent_color=”” accent_hover_color=”” bevel_color=”” border_width=”1px” shadow=”” icon=”fa-check-circle-o” icon_position=”left” icon_divider=”no” modal=”” animation_type=”0″ animation_direction=”left” animation_speed=”1″ alignment=”right” class=”” id=””]Send a request[/fusion_button]Adsorptionstrockner ROTOR - K.i.R.S.C.H.Adsorptionstrockner ROTOR - K.i.R.S.C.H.
[/fusion_text]
Dehumidification capacity at 20° C and 60% rel. humidity:
4,6 kg/h
Dehumidifying performance at 30° C and 80% rel. humidity:5,89 kg/h
Dehumidifying performance at 10° C and 70% rel. humidity:3,22 kg/h
Dehumidification capacity at 0° C and 90% rel. humidity:2,35 kg/h
Process air flow, nominal, ext. pressure:
1.000 m³/h, at 200 Pa ext.
Regeneration air flow, nominal, ext. pressure:250 m³/h, at 50 Pa ext.
Working environment temperature:-20 to +35° C
Working range humidity:10 – 100 % rF
El. heating capacity, max.:6 kW
Electrical power, max.:0,4 kW
Total power, max.:6,4 kW
Supply:3x 400V, 50 Hz
Fuse:16 A
Required switch remote control (e.g., hygrostat or remote ON):1 A (control voltage)
Hight (total):1100 mm
Width (total):400 mm
Deep (total):680 mm
Weight:63 kg
Intake process air:200 mm
Outlet process air (dry air):160 mm
Inlet regeneration air:125 mm
Outlet regeneration air (wet air):100 mm
Rotor speed:42 1/h
Noise level, with connected ducting, 1m free field:< 69 dB(A)
Filter classe:G3
Working principle:
RECUSORB
Installation:
Stationary, standing
Wet air exhaust:Required
Housing:Stainless steel, selfstanding
Maintenance accessibility:From the front and from the left
Air filter, class Luftfilter, Filterklasse:A G3 filter for the process and regeneration air, can be reached quick and easy
Fan:
One radial fan for the process and regeneration air, the fan being externally mounted on the housing, fan directly driven
Sorption rotor:SSCR-U, d 550mm x h 50mm
Rotor drive:Rotor motor with belt drive and belt tensioning device
Regeneration heater:
Electric PTC-heater, with over heat protection, two-stage (3 + 3) kW
Thermostat system:Consisting of safety temperature limiter, control thermostat and damp-air temperature limiter
Electric equipment:
All components wired to serial terminal, main switch, On / Off buttons and Man / Auto switch, heating level selector switch, light indicator for operation and fault, operating hours counter, control voltage transformer, motor protection groups, automatic backup devices
Controlling:Two-stage heating system controllable by hygrostat
Signal:Remote-ON/OFF, Collective fault message
Supply line:Without
Operating hours counter:Standard
Device connection socket:Without
 Hygrostat/Remote-ON: