Sorption dehumidifier DC-50R
- Stainless steel housing
- D-MAX sorption rotor
- Separate guidance of the process and regeneration air
- Electric PTC regeneration heating
- Ammeter for regeneration air settings
Specifications/Instructions:
Download Data sheet-DC-50_DE (394 KB)
Download Dimensions-DC-50R (56.83 KB)
Dehumidification capacity at 20 ° C and 60% rel. humidity:
|
3,0 kg/h |
Dehumidification capacity at 30 ° C and 80% rel. humidity: | 3,2 kg/h |
Dehumidification capacity at 10 ° C and 70% rel. humidity: | 2,7 kg/h |
Dehumidification capacity at 0 ° C and 90% rel. humidity: | 2,4 kg/h |
Process air flow, nominal, at ext. pressure: | 550m³/h, 150Pa |
Regeneration air flow, nominal, at ext. pressure: | 150 m³/h, 100Pa |
Working environment temperature: | -20 to +35 °C |
Working range humidity: | 10 – 100 % rH |
El. heater power, max.: | 5,0kW |
El. motor power, max.: | 0,5 kW |
El. total consumption, max.: | 5,5 kW |
Supply voltage: | 3x 400V, 50 Hz |
Fuse: | 20 / 16A |
Required switch for remote control (for example, humidistat or remote ON): | 10 A |
Height (total): | 556 mm |
Width (total): | 556 mm |
Deep (total): | 578 mm |
Weight: | 63 kg |
Inlet process air: | 160 mm |
Outlet process air (dry air): | 160 mm |
Inlet regeneration air: | 100 mm |
Outlet regeneration air (wet air): | 100 mm |
Rotor speed: | 24 rph |
Noise, with associated ducting, 1m free range: | |
Filter: | G3 |
Field of use and installation | Diverse application range, to achieve the lowest relative humidity possible, to dry air to specific value at low temperatures, with wet air exhaust to the outside |
Working principle: | CONSORB |
Installation: | Mobile and stationary, standing |
Wet air exhaust: | Required |
Housing: | Stainless steel, self-standing |
Maintenance accessibility: | From the front and from above |
Filter: | G3 filter for process and regeneration air, easy to reach |
Fan: | Separate radial fan for process and regeneration air, both fans directly driven |
Sorption rotor: | D-MAX, d 450mm x h 100mm |
Rotor drive: | Rotor motor with belt drive and belt tensioner |
Regeneration heating: | Electrical PTC heater, self-regulating with overheating protection, ammeter for easy reg.-air flow control |
Electrical equipment:
|
All components wired to terminal, On / Off and Man / auto switch, with ammeter, working hour counter and hygrostat socket, standard-configuration |
Controlling: | Prepared for hygrostat connection |
Signal: | Remote-ON/OFF |
Supply: | |
Operating hours counter: | Standard |
Device socket: | Standard |
Hygrostat/Remote-ON: |